Home > Labview Error > Labview Error Code 9

Labview Error Code 9

This is a perfect application for an enumerated type def., but we'd like an enumerated variable whose values are in the User Error Range and not simply a continuous positive progression A simpler LabView program that only uses Trigger in and Wire In functions also worked fine. I used PipeIn to write a waveform into the RAM and then output data from the RAM to the DAC. but, does it mean that the library VI can be upgraded to a new version, but cannot be downconvert to previous version? http://softacoustik.com/labview-error/labview-error-code.php

But more about those capabilities later.) The Error-Handling Package uses the convention that any numeric value incorporated in the zeroth string of the enum specifies an offset to be applied to When you use someone’s DLL, wouldn’t it be nice to be able to convert the (typically negative) C error codes to the LabVIEW User Error Code range—and lift the C comments Zero is LabVIEW's choice (and the choice of most other programming languages, as well) for the "no error" case. Sometimes, as in the case shown in Figure 3, only part of the information is available and you must fill in the rest by hand. (Or, as we did here, leave http://digital.ni.com/public.nsf/allkb/C18E6D5FFA8F0D85862568CC0067274F

Click here to catch up on TS9524 - Code Optimization and Benchmarking 0 Kudos Message 2 of 4 (1,598 Views) Reply 0 Kudos Re: LV load error code 9:VI version (13.0) In the standard error dialog, this would appear immediately after "occurred at". The second column lists the codes from the user error range (5000-9999) that you wish to assign in place of those defined by the vendor. Your cache administrator is webmaster.

But when I try to open any VI from the toolkit menu in block diagram I get the error; "VI version is later than the current LabVIEW version. .. Update Error Enum.vi is provided in the package to maintain synchrony between the error definition file and its associated enum or to create the enum in the first place. The only thing left to do is to run the examples! Getting started with LabVIEW If you are new to writing code for Phidgets, we recommend starting by running, then modifying existing examples.

How can I run a labview 7.2 vi in labview 8.2 8. Save for Previous Version tool window. Revert from a backup copy. https://forums.ni.com/t5/LabVIEW/load-error-code-9-VI-version-8-2-is-newer-than-the-LabVIEW/td-p/591705 You can determine that your device is connected to your application if you see the indicator for attached turn green and the correct serial number is displayed.

Inside the examples folder, navigate to the directory for your device. 2. An error occurred loading VI 'BK Precision 178XB Series.lvlib:Close.vi. does the DSC 8.2 module wor k ok with Labview 8.2b23 versi髇 2. Sometimes you'd like to drop an error constant of your choice onto the diagram of a VI.

Showing results for  Search instead for  Did you mean:  Reply Topic Options Subscribe to RSS Feed Mark Topic as New Mark Topic as Read Float this Topic to the Top Bookmark Thanks! United States MY ACCOUNT   INNOVATIONS SHOP SUPPORT COMMUNITY Home Community Home : Most Active Software Boards : LabVIEW : load error code 9: VI version (8.2) is newer than the LabVIEW load error code 9: VI version (8.2) is newer than the LabVIEW version (8.2b23). 0 Kudos Message 1 of 16 (3,182 Views) Reply 0 Kudos Re: load error code 9:

To facilitate this, we have upgraded our workhorse Chained Find First Error.vi to accept the new error enums interchangeably with the old-fashioned error codes (by incorporating Variant to Error Code within http://softacoustik.com/labview-error/labview-error-code-50400.php Remember that the introduction said that inconvenient features could be left out with impunity. VB code needed for running newer excel version macros in older excel versions 15. LabVIEW load error code 9: VI version (13.0) is newer than LabVIEW version (11.0)" Currently, updating LV2011 to LV2013 is not an option.

When I use the provided FrontPanel software to setup PipeIn (in XML, using okFilePipe), my program works fine. You would need to repeat this for each subsequent event of the same type you wish to have. Figure 13: Smart General Error Handler Diagram Figure 14: Adding Device Errors Figure 15: Overlapping Errors Those Extra Explanations Recall that Chained Find First Error allowed for additional explanations that appeared check over here Events work similarly to polling in LabVIEW anyway and should not cause substantial performance changes to your application.

To get around this you would need to copy the offending subVI, then change the name of the cluster object in it from "Event" to something else (your choice), change the Sorry!) Conclusion Isn't this the way the error package should work? The first time in any session that one of these error definition VIs is called, it parses the information into forms more useful to the computer (Figure 4).

Please try the request again.

And PipeIn is for loading a waveform into the RAM. I have no problem importing the FrontPanel dll into LabView 2009 or 2010. Open up any .vi of your choice in LabVIEW. Here's why!) Figure 17: Using an Offset Enum to Ignore an Error Another Demo Error Analysis Demo.vi demonstrates the various capabilities of the Smart Error Handlers.

can you share it to me?thank youbest regard,my email: [email protected] Home Categories FAQ/Guidelines Terms of Service Privacy Policy Powered by Discourse, best viewed with JavaScript enabled Products for USB Sensing and To relieve you of the need to explicitly convert things to variant type, I incorporate a red dot in VI icons at variant terminals. But I can't seem to do so in LabView 8.5 which is the one I want to use. this content That way the close subVI gets called and the Phidget will be released.

These features are available in most of the example vis we provide. 6. I just can't figure out why the FrontPanel control works but the LabView program doesn't. Figure 1. If you are really getting in to using Phidgets, you probably want our more general programming resources as well.

How to load dynamically String into a VI using LabVIEW Run-time Engine Version 7.0? 1 post • Page:1 of 1 All times are UTC Board index Spam Report Log In Trouble The pointer is identical in the case where two events of the same type are passed from a single function. Don't be concerned that mixing enums and integers will slow things down. All rights reserved.