Home > Labview Error > Labview Visa Error Codes

Labview Visa Error Codes

Contents

Showing results for  Search instead for  Did you mean:  Reply Topic Options Subscribe to RSS Feed Mark Topic as New Mark Topic as Read Float this Topic to the Top Bookmark The specified sound file could not be found. 4806 DirectX 8.0 or higher is required to run. event. To solve this issue, open Measurement & Automation Explorer (MAX) and select your serial port under Devices and Interfaces. check over here

The sound driver or card cannot accommodate the specified configuration. Enter a path to a valid palette file to write data to the file. −4400 The palette type is invalid. The Set Cursor VI also can return this error. 102 IVI invalid downcast. There is a size mismatch between the data in the reference and the data wired to the Data Value Reference Write Element border node. 1586 Compiled code is out of date. https://zone.ni.com/reference/en-XX/help/371361J-01/lverror/visa_error_codes/

Labview Error Code -1073807339

Ensure that a task is active and try again. Save any work to a new location and restart LabVIEW. VI_ERROR_FILE_IO BFFF00A2h An error occurred while performing I/O on the specified file. Add Comments 1 2 3 4 5 My Profile|Privacy|Legal|Contact NI© National Instruments Corporation.

Verify the ability name does not contain spaces. 1469 Specified ability already exists. The return type must be Void, Numeric, or String. Please tell us why. Labview Visa Read Error Additionally, can verify that you are not trying to read too many bytes by reading only 1 byte at a time.

You cannot use queues for communication between LabVIEW application instances. 1492 If you obtain a notifier reference in one application instance, you cannot use that notifier reference in another application instance. Another common error is using the wrong type of serial cable. There is already a VI in this hierarchy with this name. 1449 Arrays must have at least one dimension and a maximum of 63 dimensions. 1450 One or more untitled library http://zone.ni.com/reference/en-XX/help/371361J-01/lverror/misc_lv_error_codes/ VI_ERROR_RAW_WR_PROT_VIOL BFFF0034h Violation of raw write protocol occurred during transfer.

The input for class name is not correct or is in the wrong format. Error -1073807339 Occurred At Visa Read Parsing error. −1073807341 Invalid access mode. −1073807339 Timeout expired before operation completed. −1073807338 The VISA driver failed to properly close the session or object reference. VI_ERROR_INV_OBJECT BFFF000Eh The given session or object reference is invalid. VI_ERROR_INV_MODE BFFF0091h The specified mode is invalid.

Labview Error 1073807339

Before assuming that the system needs more memory to complete the operation, make sure the read format you are requesting is valid for the data being read. 1157 You cannot use official site VI_ERROR_ASRL_PARITY BFFF006Ah A parity error occurred during transfer. Labview Error Code -1073807339 The target version for save must be a valid LabVIEW version in the form x.x or xx.x, where x is a number. Ni Error VI_ERROR_MEM_NSHARED BFFF009Dh The device does not export any memory.

Most likely the VI is broken or one of its subVIs cannot be located. check my blog If you are sure that you have selected the correct instrument and it is responding, try disabling ID Query in the instrument driver's initialize VI. −1074003950 Error interpreting the instrument's response. Label visibility is controlled by the label owner. 1187 Internet Explorer is required for this operation but it is not installed. 1188 The static VI reference is not configured. VIs in libraries are saved in the form LIBRARYNAME_VINAME. Labview Error Handling

VI_ERROR_INTF_NUM_NCONFIG BFFF00A5h The interface type is valid but the specified interface number is not configured. VI_ERROR_INV_JOB_ID BFFF001Ch Specified job identifier is invalid. VI_ERROR_RESP_PENDING BFFF0059h A previous response is still pending, causing a multiple query error. this content This is usually due to a required driver not being installed on the system. −1073807201 The interface cannot generate an interrupt on the requested level or with the requested statusID value.

This file cannot be saved until all dependent files have been named. 1022 Wizard Template not found. 1023 Wizard template does not have a diagram. 1024 Call Instrument aborted. 1025 Application Visa Read Byte Count Verify that the VISA Resource Name, Baud rate, Data bits, Parity, and Stop bits all match the settings of your device under the port settings tab. VI_ERROR_NENABLED BFFF002Fh The session must be enabled for events of the specified type in order to receive them.

VI_ERROR_INV_PARAMETER BFFF0078h The value of some parameter--which parameter is not known--is invalid.

All rights reserved. | Cart|Help KnowledgeBase Request Supportfrom an engineer NIHome > Support > KnowledgeBase EnglishJapaneseChinese(China)SpanishChinese(Taiwan)FrenchGerman 83 ratings: 3.02 out of 5   Why Do Please Contact NI for all product and support inquiries. To correct this error, verify that the file is not in use by another application and that file permissions are set correctly. Visa Declined Codes This error also can occur if you used a model that is not officially supported by this driver.

Verify the path for each item in the items array. Another possible cause for this error is there might be a bad network connection. sorry for this question? have a peek at these guys This file cannot be saved until all dependent files have been named. 1451 One or more untitled dependencies exist.