method 1 or 3, though I still would recommend method 3) to catch that an error occurred. Absolutely! query.Drawback: It seems I get a lot of messages back in this method that aren't real errors. I'll know if I got, for example, a DDE (Device Dependant Error), but I won't know more detail than that. check over here

Generated Tue, 18 Oct 2016 16:23:59 GMT by s_ac4 (squid/3.5.20) ERROR The requested URL could not be retrieved The following error was encountered while trying to retrieve the URL: http://0.0.0.10/ Connection The framing error is most likely caused by some clock drift. The authors review the front panel controls, the Standard State Machine template, drivers, the instrument I/O assistant, error handling functions, hyperthreading, and Express VIs. Use the error cluster controls and indicators to create error inputs and outputs in subVIs. http://forums.ni.com/t5/Measurement-Studio-for-VC/Best-error-handling-for-visa-calls/td-p/954524

Labview Error Code

A leak is a leak, and if we loose 1kb every time we open/close then that needs to be fixed. You also might want the VI to retry for a certain period of time. Share this post Link to post Share on other sites Mark Yedinak 22 Extremely Active Members 22 421 posts Location:Huntley, IL Version:LabVIEW 2011 Posted March 7, 2009 QUOTE (crelf @

Just flushing the port and doing a retry would be my first attempt at handling this situation. Although this might skew the results, can you log the available memory while you're doing this? (assuming there are no issues with the logging code ) Share this post Link to Almost all I/O functions return error information. Labview Error 200279 To disable automatic error handling for the current VI, select File»VI Properties and select Execution from the Category pull-down menu.

Take care, Ben Share this post Link to post Share on other sites Create an account or sign in to comment You need to be a member in order to leave Labview Simple Error Handler Ben Share this post Link to post Share on other sites crelf 274 I'm a LAVA, not a fighter. This allows an error to be cleared without having to unbundle it and send the code to a case structure. https://forums.ni.com/t5/LabVIEW/visa-error-handling-in-serial-communication/td-p/2653305 So is method 3 as robust as it looks, or is there a combination/comprimise I can make, or another method I did not mention which is best to trap errors from

The system returned: (22) Invalid argument The remote host or network may be down. Labview Visa Error Codes Continue Learning Prev Execution Structures Finding Examples for LabVIEW Next Wir verwenden Cookies, um das Surfen auf unserer Website angenehmer zu gestalten. Can I get power supply status from the visa read/write return value? 0 Kudos Message 3 of 6 (4,363 Views) Reply 0 Kudos Re: Best error handling for visa calls? Everything work fine, but problem starts when I unplug the device from computer.Program blocks and I could not do anything.

Labview Simple Error Handler

This book is for those who wish a better understanding of virtual instrumentation concepts, its purpose, its nature, and the applications developed using the National Instrument’s LabVIEW software. dig this Share this post Link to post Share on other sites Grampa_of_Oliva_n_Eden 89 Prepper Members 89 2,767 posts Version:LabVIEW 2009 Since:2009 Posted March 12, 2009 QUOTE (TG @ Mar 10 2009, Labview Error Code Just as data values flow through a VI, so can error information. Labview Error Daqmx Poor|Excellent Yes No Document Quality?

Kontakt Rechtliche Hinweise | Datenschutz | © National Instruments Corporation. check my blog VaibhavKanchan Member ‎05-27-2012 12:18 PM Options Mark as New Bookmark Subscribe Subscribe to RSS Feed Highlight Print Email to a Friend Report to a Moderator Hi KingTermite, I hope you The power supplies are SCPI and use SCPI/GPIB commands. Visit the CRC website to download accompanying software. Labview Error Handling Best Practices

Sumathi, P. Use the LabVIEW error handling VIs, functions, and parameters to manage errors. For example, when I write a command to a GPIB instrument and I don't get any value back, I receive a timeout error (-1073807339) that breaks my loop. this content Wire the error information from the beginning of the VI to the end.

When you perform any kind of input and output (I/O), consider the possibility that errors might occur. Labview Error -1073807339 Visa Read If so, do you have a CAR#? Thanks in advance Framing Erors are generally due to issue with the transmission medium.

YourFeedback!

Code Description −1073807360 Unknown system error (miscellaneous error). −1073807346 The given session or object reference is invalid. −1073807345 Specified type of lock cannot be obtained, or specified operation cannot be performed, Kelly_R Member ‎08-03-2009 03:23 PM Options Mark as New Bookmark Subscribe Subscribe to RSS Feed Highlight Print Email to a Friend Report to a Moderator Hi KingTermite,To catch the more power All rights reserved. Labview Error 50103 Cheers,Kelly R.Applications EngineerNational Instruments 0 Kudos Message 4 of 6 (4,335 Views) Reply 0 Kudos Re: Best error handling for visa calls?

More data might be available. 1073676300 VISA received more event information of the specified type than the configured queue size could hold. 1073676407 The specified configuration either does not exist or Manual Error Handling Back to top You can choose other error handling methods. I recommend experimenting to see what error codes your application throws, or alternatively you can use the VISA error codes documentation to create the case structures needed to hande these errors. have a peek at these guys Now accompanied by LabVIEW 2011, this classic second edition, focusing on LabVIEW 8.0, delves deeply into...https://books.google.com/books/about/LabView.html?id=L-fKBQAAQBAJ&utm_source=gb-gplus-shareLabViewMy libraryHelpAdvanced Book SearchGet print bookNo eBook availableCRC PressAmazon.comBarnes&Noble.comBooks-A-MillionIndieBoundAll sellers»Get Textbooks on Google PlayRent and save

The following block diagram implements this method to watch for a particular error, and then clears that error only. Share this post Link to post Share on other sites Grampa_of_Oliva_n_Eden 89 Prepper Members 89 2,767 posts Version:LabVIEW 2009 Since:2009 Posted March 7, 2009 QUOTE (TG @ Mar 6 2009, I have an LV 8.6 machine running a test to see if this issue exists in a more recent version. At the end of the execution flow, LabVIEW reports the error.

The error in and error out clusters include the following components of information: status is a Boolean value that reports TRUE if an error occurred.